[ÊÀÊ ÍÀÑ ÍÀÉÒÈ] [ÏÐÎÅÊÒÛ] [ÍÎÂÎÑÒÈ] [ÊÎÍÔÅÐÅÍÖÈß] ÑÒÀÒÈÑÒÈÊÀ] [ÑÅÐÂÈÑÍÛÉ ÖÅÍÒÐ] [ÏÎÈÑÊ] [ÇÀÊÀÇ]

ÖÈÔÐÎÂÛÅ ÌÓËÜÒÈÌÅÒÐÛ
608

ÂÎÇÌÎÆÍÎÑÒÈ

  • 4 4/5 Digit, Dual Display

  • 50,000 Count True RMS

  • True RMS for AC or AC+DC

  • Accuracy : 0.05%(DC Volt)

  • Auto Calibration

  • PC Interface with RS232C

  • LCD Backlight

  • New style of bar graph display based on binary bit expression method

  • ±Peak detection mode for high speed signal capture

  • Easy determination on with GO/NG mode

  • Low battery indication

ÕÀÐÀÊÒÅÐÈÑÈÊÈ

DC mV & V

Function

Range

Accuracy

Input Impedance

Protection

DC mV

500.00mV 2500.0mV

0.05%+5d

1Gohm

MAX.250VAC or DC
(5kohm PTC)

DCV

5.0000V 50.000V 500.00V 1000.0V

About 10.5 Mohm About 10 Mohm About 10 Mohm About 10 Mohm

MAX.1000VDC or
750VAC
(10Mohm)

AC mV &

Function

Range

Accuracy for each freguency band

50~
500Hz

up to  1kHz

up to 5kHz

up to 10kHz

up to 20kHz

AC mV

500.00mV

0.75%+20d for<400mV 1%              for >400mV

1.5% for > 50mV

2% for >50mV

3% for 50mV

AC V

5.0000V
50.000V
500.00V
750.0V

0.75%+20d

1%
for ACV Level
more than 10% of
Full Scale Reading

2%
for ACV
>10% of
Full Scale

Not
Specified

Wave Form

Crest Factor

Additional Error

Square
Sine
Triangle
Others
 

1
1.414
1.73
2
3

0.20%
0%
0.30%
0.50%
1.70%

AC + DC mV & V

Function

Range

Accuracy for each freguency band

50~
500Hz

up to  1kHz

up to  5kHz

up to  10kHz

up to  20kHz

AC + DC mV

500.00mV

1.5%+50d for<300mV 2.0%         for >300mV

2.5% for > 50mV

3.5% for > 50mV

4.5% for > 50mV

AC + DC V

5.0000V
50.000V
500.00V
750.0V

2.0% + 50d

2.5%
for AC+DCV Level
more than 10% of
Full Scale Reading

3.5%
for AC+DCV
>10% of
Full Scale

Not
Specified

DC current

Function

Shunt

Range

Accuracy

Protection

DC uA
DC mA
DC A

100 ohm
1 ohm
10 Mohm

5000.0 uA
500.00 mA
10.000 A

0.2% + 5d

1A/600V Fast Fuse&
22V M.O.Varistor

0.5% + 5d

15A/600V Fast Fuse

AC current

Function

Shunt

Range

Accuracy

Protection

AC uA
AC mA
AC A

5000.0 uA
500.00 mA
10.000 A

50Hz to 1kHz

0.75%+20d
for<40000count
1% for>40000count

1A/600V Fast Fuse&
22V M.O.Varistor

15A/600V Fast Fuse

AC + DC current

Function

Range

Frequency

Accuracy

Protection

AC + DC uA
AC + DC mA
AC A

5000.0 uA
500.00 mA
10.000 A

DC to 1kHz

1.5% + 50d
for<30000count
2% for>30000count

1A/600V Fast Fuse&
22V M.O.Varistor

15A/600V Fast Fuse

  • Resistance

  • Range

    Resol.

    Accuracy

    Open / Short

    Protection

    50.00 OHM

    0.01 ohm

    1.0% + 20d

    2.5V / 1.4mA

    250VAC or DC
    (500ohm PTC)

    5.0000 K
    50.000 K
    500.00 K
    50000 M

    0.1 ohm
    1 ohm
    10 ohm
    100 ohm

    0.2% + 5d

    2.5V / 1.7mA
    2.5V / 240uA
    2.5V / 25uA
    2.5V / 2.5uA

    50.000 M

    1k ohm

    1.0% + 10d

    2.5V / 250nA

  • LV ohm (Low Voltage OHM)
  • Range

    Resol.

    Accuracy

    Open / Short

    Protection

    5.000 k
    50.00 k
    500.0 k
    5.000 M

    1 ohm
    10 ohm
    100 ohm
    1k ohm

    0.2% + 5d  

    0.25V / 170uA
    0.25V / 24uA
    0.25V / 2.5uA
    0.25V / 250uA

    250VAC or DC
    (500 ohm PTC)

    50.00 M

    10k ohm

    1.0% + 10d

    0.25V / 25nA

  • nS
  • Range

    Resol.

    Accuracy

    Open / Short

    Protection

    500.0 nS

    0.1 nS

    3.0% + 5d

    2.5V / 25nA

    250VAC or DC

  • Continuity
  • Range

    Input

    Response

    Accuracy

    Protection

    5 kohm
     
    50 kohm
     
    500 kohm
     
    5 Mohm
     

    short
    open
    short
    open
    short
    open
    short
    open

    Buzz On
    Buzz Off
    Buzz On
    Buzz Off
    Buzz On
    Buzz Off
    Buzz On
    Buzz Off

    < 5 ohm
    > 15 ohm
    < 50 ohm
    > 100 ohm
    < 500 ohm
    > 1 kohm
    < 5 kohm
    > 10 kohm

    250VAC or DC
    (500ohm PTC)

  • Zener Diode
  • Range

    Accuracy

    Test Current

    Open circuit V

    Protection

    15.000V

    5% + 10d

    1mA

    15 to 22V

    250VAC or DC
    (500 ohm PTC)

  • Capacitance
  • Range

    Resol.

    Accuracy

    Testin Time

    Protection

    5.000 nF
    50.00 nF
    500.0 nF
    5.000 uF
    50.00 uF
    500.0 uF
    5.000 mF

    1 pF
    10 pF
    100 pF
    1 nF
    10 nF
    100 nF
    1 uF

    5% + 10d
    2% + 10d
     
    2% + 5d
     
    3% + 10d
     

    1.1 Sec

    250 VAC or DC
    (500 ohm PTC)

    Variable
    (1.1 ~ 10 Sec.)

  • Frequency
  • Range

    Resol.

    Accuracy

    Input Impedance

    Protection

    50.00 Hz
    500.0 Hz
    50.000 kHz
    500.00 kHz
    5.0000 kHz

    0.01 Hz
    0.1 Hz
    1 Hz
    10 Hz
    100 Hz

    0.01% + 5d

    10Mohm // 1nF

    500VAC or DC
    (1kV 1nF Capacitor
    Parallel with 10M
    1/2W Resistor)

  • Pulse Width
  • Range

    Resol.

    Accuracy

    Input Impedance

    Protection

    200.00 mS

    10 uSec.

    0.1% + 5d

    10Mohm // 1nF

    500VAC or DC

  • Duty cycle
  • Range

    Resol.

    Accuracy

    Pulse width

    Protection

    100.00%

    0.01%

    0.1% + 5d

    0.1ms ~ 200ms

    500VAC or DC

  • Temperature
  • Range

    Resol.

    Range

    Accuracy

    Protection

    'C

     
    'F
    'K

    0.1'C

     
    0.1'F
    0.1'F

    -20 ~ 0'C
    0 ~ 150'C
    150 ~ 1200'C

     ±3'C
     ±2'C 
     ±2%  

    Max. 500VAC or
    DC for V terminal,
    1A 600V Fast Fuse
    for mA terminal

    'F = 32 +(9/5 x 'C)
    'K = 'C + 273.1

Peak +/- detection

Function

Accuracy

Remark

DCmA
DCV
DcuA
DCmA
DCA

Less than 10% for peak with
>5ms of duration and with
>10% of full scale of each range

 

  • AD conversion
    50,000 Count Resolution
    0.05% Basic Accuracy and 50ms of Sampling Time

  • Pre-Requisition for Normal Use
    <1 Year Calibration Cycle 23+5'C of Ambient Temperature <90%RH of Humidity  & Non-condensing

  • Accuracy Expr.
    ±(% of Reading + Least Significant Digits)

  • Bar-graph
    Binary 17 Bit Expression of Mian Digit Decimal

  • Polarity Indication
    - For Negative, None for Positive

  • LCD Update Rate
    0.5 second typ. Exception for the Below
    Functions 1~10 second for Hz,PW,capacitance

  • Memory Locations
    10 Memories for 10 Measured Data

  • Power Source :
    9V Battery , Carbon Zinc or Alkaline Neda 1604,6F22,006P

  • Auto Power Off
    15 min. Typ. After Last Operation of Key or switch

  • Auto Back Light Off
    Automatically Turns Off Typically 30 Sec. after the Back Light Turned on by Pressing the Light Key.

  • Power Consumption & Battery Life
    1) Normal Operating : 7mA typ. which is
        Equivalent to 36 Hours of Continuous
        Use with general Zinc-Carbon Type 9V
        Battery
    2) Auto Power Off : 70uA typ.
        (Equiv. to 5 Month)
    3) Power Switch Off : 7uA Max.
        (Equiv. to 4Year)

  • Safety
    CE Requirement

  • Temp. Coefficient
    <0.1 x Accuracy Spec. / 'C for 0~18'C and
    28~40'C(32~64.4'F and 82.4~104'F)

  • Operating Temp.
    0~40'C(32~104'F)

  • Relative Humidity
    <90%RH at 0~28'C(32~82.4'F),Non Condensing
    <80%RH at 28~40'C(82.4104'F),Non Condensing

  • Storage Temp.
    -20~60'C at ,70%RH & Non Condense

  • Basic Accessary
    Test Leads, User Manual, Gift Box, Holster
    RS232C CD for win95 & win3.1
    RS232C Adaptor Cable

  • Option Accessary
    Temp. Adaptor (608TA)
    Temp. Probe(K)

  • Low Battery Detect
    Battery Indicator on LCD Appearse at Below 6±1V

  • Physical Size (H x W x D)
    Mian Unit(Net) : 203.5 x 94.0 x 43.2mm
    With Holster : 216.5 x 104.5 x 58.0mm

  • Physical Weight
    Main Unit(Net) : 417g(14.7 oz)
    With Holster : 557g(1 lb 3.6oz)